1、Specifications
Operating voltage: 3.0-3.6V
Operating temperature: -40~+85℃
Power Consumption: Less Than 10 mA
2、Metering function
- 2 independent oversampling ∑/∆ ADCs
- Active energy error: <1% @ 1000:1 dynamic range
- Voltage/current RMS error: <1% @ 500:1 dynamic range
- Measurements: full-wave V/I RMS full-wave active/reactive power frequency
- DC metering supported
3、Features
- Built-in current sampling resistor calibration-free of user-level errors maximum metering current: 20A.
- Support full-wave voltage/current RMS value measurement full-wave active and reactive power measurement frequency measurement
- The zero-crossing voltage signal is synchronized with data upload
- Upload metering data every 4 cycles.
- Independent CF output with a pulse constant of 4000 imp/kWh.
- 50Hz/60Hz Self-adaptive
- Crystal-free